This electronic flyer highlights our capabilities and activities in the area of SwRI Flowing Gas Test Facility. Please sign our guestbook. For additional information, e-mail Shane P. Siebenaler, Southwest Research Institute.

SwRI Flowing Gas Test Facility


Subsurface Safety Valve Installed in SwRI Flowing Gas Test Facility


Evaluations Available

  • Subsurface oil and gas production safety valve testing
  • Oil and gas production annulus control valve testing
  • Subsurface gas storage well safety valve testing
  • Control valve testing and research
  • Gas transmission line emergency shutdown valve testing and research

Deliverables

  • Hard copy of test data and summary sheet
  • Test results can be provided within a day of the test

System Capabilities

  • Maximum flow rate: approximately 185 x 106 SCFD at 2,200 psig
  • Maximum operating pressure: up to 3,000 psig
  • Duration of run: 5 seconds to several minutes, depending on flow rate

Measurement Capabilities

  • Flow measurement:
    • 3-inch orifice meter upstream of test section with orifice plates ranging from 0.25 inch to 2.25 inch
    • 8-inch annubar upstream of test section 
  • Static pressure measurement: 0-3,000 psig
  • Differential pressure: 0-2,000 psid (across test section)
  • Temperature measurement: 0-125 °F
  • Hydraulic control fluid pressure: 0-10,000 psig

Special Features

  • Flow medium: nitrogen gas, stored in:
    • 625 ft3 vessel at up to 3,000 psig
    • 500 ft3 vessel at up to 3,000 psig 
  • Gas charging system including 6,000-gallon liquid nitrogen storage tank
  • Blowdown operation, with remote operation of controls and data acquisition
  • Eighteen-foot normally vertical test section--flexibility to allow other configurations for special applications
  • Data acquisition: 12-bit, PC-based data acquisition system


This flyer was published in December 1997. For more information about the SwRI Flowing Gas Test Facility, contact Shane P. Siebenaler, Research Engineer, Phone (210) 522-5758, or J. Chris Buckingham, Manager, Phone (210) 522-3307, Fax (210) 681-9661, Mechanical Engineering Division, Southwest Research Institute, P.O. Drawer 28510, San Antonio, Texas 78228-0510.