SwRI Metering Research Facility
Operational Ranges

Operational Parameter

HPL

LPL

Max. Flow Rate (standard m3/hr)
Max. Flow Rate (scfh)

201,000
7,100,000

18,800
663,000

Max. Flow Rate (actual m3/hr)
Max. Flow Rate (acfh)

2,340
82,800

1,270
45,000

Pressure (kPa)
Pressure (psig)

1,035 to 7,600
150 to 1,100

340 to 1,310
50 to 190

Gas Temp (degrees C)
Gas Temp (degrees F)

4 to 50
40 to 120

4 to 50
40 to 120

Pipe Diameter (millimeters)
Pipe Diameter (inches)

50 to 500
2 to 20

25 to 200
1 to 8

Specific Gravity

0.55 to 0.97

0.55 to 0.97

 

Fluids and Machinery Engineering Department
Metering Research Facility separate.gif (834 bytes) Mechanical Engineering Division
SwRI Technical Divisions separate.gif (834 bytes) SwRI Home